Green deuterated ammonia Pilot plant
Description
This pilot plant is a dedicated configuration of Vinci Technologies’ AMS Ammonia Synthesis platform for deuterated ammonia (ND₃) production. It supports catalyst testing, kinetic studies and process development, with controlled high-pressure gas delivery, unreacted gas recirculation and product measurement.
Application and objectives
The unit enables researchers to evaluate iron-based and ruthenium catalysts during deuterated ammonia synthesis (N₂ + 3D₂ ⇌ 2ND₃) up to a production capacity of 0.5 kg/h. Independent adjustment of deuterium and nitrogen feed rates, loop recirculation, pressure and reactor temperature profile allows the influence of operating conditions to be investigated. Gas and liquid recovery supports product characterisation and material balances.
Feed preparation and gas recirculation
High-pressure deuterium (D₂) and nitrogen (N₂) are each supplied at up to 20 NL/min and 200 barg through thermal mass flow controllers equipped with automatic shut-down valves. Unreacted gas recovered after ammonia separation is 100 % recycled via a closed-loop recirculation module. This loop comprises an electrical and hydraulic driven compressor (120 NL/min at 200 bar), a binary gas sensor and a Coriolis mass flow controller rated up to 6.0 kg/h.
Reaction section
A 3D-printed static mixer and a 2.5–3 kW electric preheater condition the feed gases between 20 and 450 °C before they enter an upflow, pseudo-isothermal multi-tubular reactor. The Inconel 625 configuration accommodates 0.7 to 1.3 L of catalyst across four parallel tubes totalling 4.5 L, operating at a GHSV of 10,000 to 20,000 h⁻¹ with a 20 % single-pass conversion. A five-zone radiant furnace, five radial thermocouples and a thermowell provide temperature control and monitoring.
Separation and product measurement
A cooling stage and a Vinci three-stage high-pressure separator (up to 200 barg, with chilled jacket) recover liquid ND₃ from the reactor effluent, followed by a medium-pressure separator/stripper rated up to 25 barg. Liquid deuterated ammonia passes through a Coriolis mass flow meter (0.2–2.0 kg/h, ±0.6 %) with density monitoring and a transfer pump for collection. Vent gas is metered by a Coriolis mass flow meter (up to 2 kg/h, ±0.5 %) equipped with a pressure regulation system.
Operating basis and supervision
Operating limits are 150 barg and 700 °C (200 barg design); actual test conditions typically range from 400 to 700 °C and 100 to 150 barg depending on the selected catalyst and experimental programme. A PLC, supervision workstation and six-tier safety system provide unattended process control and monitoring.